In US law, clinical decision support (CDS) software is software that supports or provides recommendations to a health care professional about prevention, diagnosis or treatment. Under section 520(o)(1)(E) of the FD&C Act, CDS software that meets four criteria — it doesn't process medical images or signals, it displays or analyzes medical information, it supports a health care professional's recommendation, and it lets the professional independently review the basis — is excluded from the device definition; other CDS software can be a device.
- USA
- AI
In one sentence
FDA CDS software: decision support for clinicians; it is not a device only if it meets all four criteria of FD&C Act section 520(o)(1)(E).
Example
Software that lists guideline-based treatment options for a clinician, with the guideline cited and the patient data it used, may be non-device CDS; software that analyzes a CT image to flag a stroke is a device, because it processes a medical image.
Explained in context
This term is a station of a mini course
- The medical-device evidence chain: from intended purpose to post-market evidenceStation: FDA pathway · Is the software a device?Start the course
Context cards connect this term with others to answer one question. Also in British English and German.
How it applies
- Four statutory criteria: All four must be met for the exclusion. Failing one — for example, processing a signal such as an ECG waveform — keeps the function in the device definition.
- Guidance revised in 2026: FDA's revised final guidance of January 6, 2026 (minor correction of January 29, 2026) superseded the 2022 version. Among other points, it describes enforcement discretion for some functions that give a single recommendation and moves the question of time-critical decisions to the fourth criterion. It addresses software for health care professionals, not patient-facing tools.
- Independent review is a documentation question: The fourth criterion depends on whether the professional can see the basis of a recommendation — inputs, logic, sources and limits. That is user information, written into the interface and the labeling.
- Technical documentation: Describe for each recommendation what it is based on, which data it used and where it shouldn't be relied on, in the interface itself, not only in a separate manual.
FDA CDS vs. EU decision support software