Glossary Updates16 new terms added to the glossaries · November 12, 2026, 21:23 CET
AI TechDocKnowledge

Glossary · EU medical devices: MDR

Medical device vs. IVD: MDR vs. IVDR

Also known as: MDR vs. IVDR, IVDR vs. MDR, Medical device vs. in vitro diagnostic

In EU law, medical devices fall under the Medical Device Regulation (EU) 2017/745 and in vitro diagnostic medical devices under the In Vitro Diagnostic Medical Devices Regulation (EU) 2017/746. An IVD is a device intended for the in vitro examination of specimens derived from the human body; all other medical devices are governed by the MDR.

  • EU
  • MDR
  • IVDR

In one sentence

MDR covers medical devices, IVDR covers in vitro diagnostics that examine specimens from the body. Classes, evidence and deadlines differ.

Example

A company makes a blood glucose meter with test strips and a separate reusable insulin pen: the meter and strips are IVDs under the IVDR (Annex VIII rules, classes A to D), the reusable pen is a medical device under the MDR (classes I to III).

How it applies

  • Dates: The MDR has applied since May 26, 2021; the IVDR since May 26, 2022. Both have separate transition periods.
  • Classification: MDR classes I (with Is, Im, Ir), IIa, IIb and III under 22 rules; IVDR classes A, B, C and D under 7 rules, both in Annex VIII. See MDR classification and IVDR classification.
  • Evidence: The MDR requires clinical evaluation and, after market entry, PMCF. The IVDR requires performance evaluation (scientific validity, analytical and clinical performance) and PMPF.
  • Public summaries: The MDR has the SSCP for implantable and class III devices; the IVDR has the summary of safety and performance (SSP) for class C and D devices.
  • Shared structure: Economic operators, PRRC, UDI, EUDAMED, technical documentation (Annexes II and III) and post-market surveillance follow the same pattern in both, often with shifted article numbers.
  • Technical documentation: Cite the correct regulation and article numbers; an article number from the MDR often points to a different topic in the IVDR, for example Article 32 MDR (SSCP) vs. Article 29 IVDR (SSP).

Medical device vs. IVD

An IVD is legally a kind of medical device, but it is regulated by its own regulation. The test is what the product examines: specimens outside the body (blood, tissue, urine) make it an IVD; acting on or in the body makes it an MDR device. Software that analyzes IVD results for a medical purpose may itself be an IVD; see medical device software.

By knowledge.aitechdoc.world · Published September 25, 2026 · Last reviewed

Source: Regulation (EU) 2017/745 on medical devices; Regulation (EU) 2017/746 on in vitro diagnostic medical devicesLaw in force: Binding legislation that applies as of the review date.

Definitions follow the cited standards and specifications. Where a source is a copyrighted publication, such as an ISO, IEC or EN standard, the definition is a close paraphrase, not a verbatim quotation, so as not to infringe copyright. We recommend reading the original publication. The sections “How it applies” are editorial commentary by AI TechDoc Knowledge and are not part of any standard.

Seen a mistake? Send us a note!