Glossary · Functional safety
Redundancy
Also known as: redundant design, multi-channel architecture
German: Redundanz
In functional safety, redundancy is the use of multiple independent channels or elements so that a single failure does not cause loss of the required function. It is effective only if the channels are sufficiently independent and faults are detected.
- Functional safety
- Systems engineering
In one sentence
Redundancy uses multiple independent channels so that one failure does not remove a required safety function.
Example
Two contactors in series switch off the motor of a conveyor; if one contact welds, the other still interrupts the power, and feedback monitoring reveals the welded contact.
How it applies
- Functional safety: Redundancy is the basis of Categories 3 and 4 in ISO 13849-1 and of hardware fault tolerance in IEC 61508 and IEC 62061.
- Integrated systems: Redundancy without detection only postpones failure. The first fault must be found by diagnostics or a test before a second fault occurs.
- Evidence: Independence has to be shown, not assumed. The common-cause failure assessment is the evidence that the channels do not fail together.
- Technical documentation: Wiring diagrams, spare part rules and maintenance steps must keep the channels separate. A shortcut during repair can reduce a two-channel design to one channel.
Redundancy vs. diversity
Redundancy provides more than one channel. Diversity makes those channels different, which also covers shared design flaws.
In risk assessment, PL analysis and security analysis
- Risk assessment (CE): Redundancy is how a control system keeps a safety function after one fault. The risk assessment names the safety functions whose required PL or SIL makes a second channel necessary.
- PL analysis: Category 3 and Category 4 of ISO 13849-1 are two-channel structures. Redundancy only counts together with diagnostic coverage (a fault in one channel must be detected) and with measures against common-cause failure (score of at least 65 points under Annex F).
- Security analysis: Two channels that share a network, an engineering station or a firmware image share the attack path – an attack is a common cause that the CCF score does not cover. Assess redundant paths separately under IEC 62443 (zones and conduits, integrity of programs and firmware) and protect the access to both channels.
Naming this term in a document never shows conformity; the risk assessment, the validation of the safety functions and the security risk assessment do. EN 50742 is a CENELEC draft as of the review date: it is neither law nor a source of presumption of conformity.