Glossary Updates16 new terms added to the glossaries · November 12, 2026, 21:23 CET
AI TechDocKnowledge

Glossary · EU medical devices: MDR

Claims matrix (medical devices)

Also known as: Claims matrix, Claims-to-evidence matrix, Claims traceability matrix

In medical device practice, a claims matrix is a controlled list of every statement a manufacturer makes about a device — on the label, in the instructions for use, in marketing material and on the website — with, for each claim, the supporting evidence, its approval status and the places where it is used. It is a working tool, not a document required by name.

  • EU
  • USA
  • MDR
  • Technical documentation

In one sentence

A claims matrix lists every claim made about a device with its evidence, its approval and where it appears, so no claim outruns the evidence.

Example

The claim “detects 95 % of significant arrhythmias” is listed once, linked to the clinical study table that supports it, approved by regulatory affairs, and marked as used in the IFU, the sales brochure and the product page; when the study is updated, all three uses are found at once.

Explained in context

This term is a station of a mini course

  • The medical-device evidence chain: from intended purpose to post-market evidenceStation: Claims as controlled informationStart the course

Context cards connect this term with others to answer one question. Also in British English and German.

How it applies

  • Article 7 MDR: Labeling, IFU, making available and advertising must not mislead about the device's intended purpose, safety and performance — for example by ascribing functions it doesn't have or failing to inform about a likely risk. A claim outside the evidence is an Article 7 question.
  • One claim, many places: The same sentence appears in the IFU, the SSCP, the brochure, the website and the sales training. The matrix makes those uses findable.
  • Evidence side: Each claim points to the evidence that supports it: clinical data, bench tests, usability results. Claims about performance or clinical benefit have to match the clinical evaluation.
  • Technical documentation: Treat claims as controlled content units with identifiers, reused rather than retyped. An answer function that quotes product information must quote approved claims only.

Claims matrix vs. claim (assurance)

In safety assurance, a claim is a statement in an assurance case that arguments and evidence support. A claims matrix in medical devices manages product claims made to users and the market. Both connect statements to evidence; the matrix adds where each statement is published.